Electrical Data
Capacitance range: 1000 pF to 1.0 µF
Rated voltage: 300VAC
Continuous DC voltage* (general guide):
< 1000V
Capacitance tolerances: ±20%, ±10%, ±5%
Operating temperature range: -55°C to +105°C
Climatic test category: 55/105/56 in accordance with IEC
Passive flammability class:
B for capacitors with V > 1750 mm
3
C for capacitors with V
< 1750 mm
3
Insulation resistance at +20°C:
C
< 0.33 µF:
> 1.5 x 10
4 MΩ
C > 0.33 µF:
> 5000 sec (MΩ x µF)
Measuring voltage: 100V/1 min.
Dissipation factors at +20°C: tanδ
at f |
C < 0.1 µF |
0.1 µF < C < 1.0 µF |
1kHz
10kHz
100kHz |
< 18 x 10-4
< 20 x 10-4
< 100 x 10-4 |
< 20 x 10-4
< 60 x 10-4
- |
Test specifications: In accordance with IEC 60384-14
Maximum pulse rise time: 100 V/µsec for pulses equal to a voltage amplitude with √
2 x 300VAC = 425V according to IEC 60384-14
Test voltage: 2700VDC, 2sec
Reliability: Operational life > 300000 hours. Failure rate < 2 fit (0.5 x U
r and 40°C)
Approvals:
Country |
Authority |
Specification |
Symbol |
Approval-No. |
Germany
USA/Canada |
VDE
UL |
IEC 60384-14/4
UL 60384-14
CAN/CSA-E60384-14 |
|
40008997
E 134915 |
* If safety-approved EMI suppression capacitors are operated with a DC voltage being above the specified AC voltage rating the given approvals are no longer valid (IEC 60384-14).
Furthermore the permissible pulse rise time du/dt (F
max.) will be subject to a reduction according to
F
max. = F
r x √
2 x U
AC / U
DC
if the DC operating voltage U
DC is higher than √
2 x U
AC
Mechanical Tests
Pull test on pins: 10 N in direction of pins according to IEC 60068-2-21
Vibration: 6 hours at 10...2000Hz and 0.75mm displacement amplitude or 10g in accordance with IEC 60068-2-6
Low air density: 1kPa = 10 mbar in accordance with IEC 60068-2-13
Bump test: 4000 bumps at 390 m/sec
2 in accordance with IEC 60068-2-29
Packing
Available taped and reeled
General Data