Electrical Data
Capacitance range: 100 pF to 4.7 µF (E12-values on request)
Rated voltages: 400VDC, 630VDC, 1000VDC, 1250VDC, 1600VDC, 2000VDC, 4000VDC, 6000VDC
Capacitance tolerances: ±20%, ±10%, ±5% (other tolerances are available subject to special enquiry)
Operating temperature range: -55°C to +105°C
Climatic test category: 55/100/56 in accordance with IEC
Insulation resistance at +20°C: Measuring voltage: 100V/1 min.
C 
< 0.1 µF: 
> 1 x 10
5 MΩ 
C > 0.1 µF: 
> 30000 sec (MΩ x µF) 
Test voltage: 2sec
| PCM | < 4000VDC | 4000VDC | 6000VDC | 
| < 37.5 > 37.5
 | 2 Ur 2 Ur
 | 2 Ur 1.6 Ur
 | 1.6 Ur 1.2 Ur
 | 
Dielectric absorption: 0.05%
Dissipation factors at +20°C: tan δ
| at f | C < 0.1 µF | 0.1 µF < C < 1.0 µF | C > 1.0 µF | 
| 1kHz 10kHz
 100kHz
 | < 5 x 10-4 < 6 x 10-4
 < 10 x 10-4
 | < 5 x 10-4 < 6 x 10-4
 -
 | < 5 x 10-4 -
 -
 | 
Maximum pulse rise time:
| Capacitance pF/µF
 | max. pulse rise time V/µsec at TA < 40°C | 
| 400VDC | 630VDC | 1000VDC | 1250VDC | 1600VDC | 2000VDC | 4000VDC | 6000VDC | 
| 100...220 330...680
 1000...2200
 3300...6800
 0.01 ...0.022
 0.033...0.068
 0.1...0.22
 0.33...0.68
 1.0...2.2
 3.3...4.7
 | - -
 29000
 9000
 9000
 9000
 7000
 6000
 5000
 2500
 | - -
 29000
 14000
 11000
 11000
 11000
 10000
 6600
 -
 | - -
 29000
 27000
 11000
 11000
 11000
 11000
 8300
 -
 | - -
 29000
 29000
 11000
 11000
 11000
 11000
 9500
 -
 | 56000 51000
 46000
 29000
 11000
 11000
 11000
 11000
 11000
 -
 | 56000 56000
 51000
 29000
 13000
 11000
 11000
 11000
 -
 -
 | - 56000
 51000
 29000
 13000
 13000
 13000
 -
 -
 -
 | - 56000
 51000
 29000
 13000
 13000
 13000
 -
 -
 -
 | 
Voltage derating: A voltage derating factor of 1.35% per K must be applied from +85°C for DC voltages and from +75°C for AC voltages.
Reliability: Operational life > 300000 hours. Failure rate < 1 fit (0.5 x U
r and 40°C)
Mechanical Tests
Pull test on pins: 
d 
< 0.8 Ø: 10 N in direction of pins
d > 0.8 Ø: 20 N in direction of pins
according to IEC 60068-2-21
Vibration: 6 hours at 10...2000Hz and 0.75mm displacement amplitude or 10g in accordance with IEC 60068-2-6
Low air density: 1kPa = 10 mbar in accordance with IEC 60068-2-13
Bump test: 4000 bumps at 390 m/sec
2 in accordance with IEC 60068-2-29
Packing
Available taped and reeled up to and including case size 15x26x31.5 / PCM 27.5mm.