Electrical Data
Capacitance range: 100 pF to 0.01 µF (E12-values on request)
Rated voltages: 63VDC, 100VDC, 250VDC, 400VDC
Capacitance tolerances: ±20%, ±10%, ±5%, ±2.5%
Operating temperature range: -55°C to +100°C
Test specifications: In accordance with IEC 60384-13
Climatic test category: 55/100/21 in accordance with IEC
Insulation resistance at +20°C:
> 3 x 10
5 MΩ
Measuring voltage:
U
r = 63V: U
test = 50 V/1 min.
U
r > 100V: U
test = 100 V/1 min.
Test voltage: 2 U
r, 2 sec
Maximum pulse rise time: 1000 V/µsec.
Dielectric absorption: 0.05%
Temperature coefficient: -200 x 10
-6/°C (typical)
Dissipation factors at +20°C: tanδ
at f |
C < 0.01 µF |
1kHz
10kHz
100kHz |
< 5 x 10-4
< 6 x 10-4
< 8 x 10-4 |
Voltage derating: A voltage derating factor of 1.35% per K must be applied from +85°C for DC voltages and from +75°C for AC voltages.
Reliability: Operational life > 300000 hours. Failure rate < 5 fit (0.5 x U
r and 40°C)
Mechanical Tests
Pull test on pins: 10 N in direction of pins according to IEC 60068-2-21
Vibration: 6 hours at 10...2000Hz and 0.75mm displacement amplitude or 10g in accordance with IEC 60068-2-6
Low air density: 1kPa = 10 mbar in accordance with IEC 60068-2-13
Bump test: 4000 bumps at 390 m/sec
2 in accordance with IEC 60068-2-29
Packing
Available taped and reeled.
General Data