Electrical Data
Capacitance range: 3300 pF to 1.0 µF (E12-values on request)
Rated voltages: 63VDC, 100VDC, 250VDC, 400 VDC
Capacitance tolerances: ±20%, ±10%, (±5% available subject to special enquiry)
Operating temperature range: -55°C to +105°C
Test specifications: In accordance with IEC 60384-2
Climatic test category: 55/100/21 in accordance with IEC
Insulation resistance at +20°C. Measuring time: 1 min.
Ur |
Utest |
C < 0.33 µF |
0.33 µF< C < 1.0 µF |
63 VDC |
50 V |
>3.75 x 103 MΩ
|
> 1250 sec (MΩ x µF)
|
>100 VDC |
100 V |
>1 x 104 MΩ
|
- |
Test voltage: 1.6 U
r, 2 sec
Maximum pulse rise time:
Capacitance
pF/µF |
max. pulse rise time V/µsec |
3300 ...6800
0.01 ...0.022
0.033...0.068
0.1...0.33
0.47...1.0 |
100
50
30
20
15 |
Dissipation factors at +20°C: tanδ
at f |
C < 0.1 µF |
0.1 µF< C < 1.0 µF |
1 kHz
10 kHz
100 kHz |
< 8 x10-3
< 15 x10-3
< 30 x10-3 |
< 8 x10-3
< 15 x10-3
- |
Voltage derating: A voltage derating factor of 1.25% per K must be applied from +85°C for DC voltages and from +75°C for AC voltages.
Reliability:
Operational life > 300000 hours. Failure rate < 2 fit (0.5 x U
r and 40°C)
Mechanical Tests
Pull test on pins: 10 N in direction of pins according to IEC 60068-2-21.
Vibration: 6 hours at 10...2000 Hz and 0.75mm displacement amplitude or 10g in accordance with IEC 60068-2-6
Low air density: 1kPa = 10 mbar in accordance with IEC 60068-2-13
Bump test: 4000 bumps at 390 m/sec
2 in accordance with IEC 60068-2-29
Packing
Available taped and reeled.
General Data