Electrical Data
Capacitance range: 1000 pF to 0.1 µF (E12-values on request)
Rated voltages: 250VAC, 300VAC
Continuous DC voltage* (general guide):
250VAC:
< 1000V
300VAC:
< 1250V
Capacitance tolerance: ±20%
Operating temperature range: -40°C to +110°C
Climatic test category: in accordance with IEC
250VAC: 40/110/56/C
300VAC: 40/110/56/B
Insulation resistance at +20°C:
> 12 x 10
3 MΩ
Measuring voltage: 100V/1 min.
Dissipation factors: tanδ
< 13 x 10
-3 at 1kHz and +20°C
Test specifications: In accordance with IEC 60384-14
Test voltage: 2400VDC, 2sec
Maximum pulse rise time 250 VAC: for pulses equal to a voltage amplitude according to IEC 60384-14 with √
2 x 250VAC = 355V
Capacitance
pF/µF |
Pulse rise time V/µsec
max. operation |
1000...4700
6800...0.022 |
2500
1750 |
Maximum pulse rise time 300 VAC: for pulses equal to a voltage amplitude according to IEC 60384-14 with √
2 x 300VAC = 425V
Capacitance
pF/µF |
Pulse rise time V/µsec
max. operation |
1000...4700
6800...0.015
0.022...0.1 |
2500
1850
600 |
Reliability: Operational life > 300000 hours. Failure rate < 1 fit (0.5 x U
r and 40°C)
Approvals:
Authority |
Specification |
Symbol |
Approval-No. |
UL/Demko
UL |
EN 60384-14
UL 60384-14
CAN/CSA-E60384-14 |

 |
ENEC-02833 (250 VAC)
ENEC-02399 (300 VAC)
E 100438 |
* If safety-approved EMI suppression capacitors are operated with a DC voltage being above the specified AC voltage rating the given approvals are no longer valid (IEC 60384-14).
Furthermore the permissible pulse rise time du/dt (F
max.) will be subject to a reduction according to
F
max. = F
r x √
2 x U
AC / U
DC
if the DC operating voltage U
DC is higher than √
2 x U
AC
Packing